  • The ability to back purge the sample point ensures optimal retrieval of a representative liquid sample.
  • The needle purge ensures there is no residue or build up in the needle after sample retrieval.
  • The DPM type sampler in back & needle purge configuration allows purge gas to flow through the sampler ensuring a fresh sample and finally to purge the needle assembly at a recommended maximum operating pressure of 8 bar.
  • This liquid sampler offers one-handle operation, providing safety for the operator and zero emission.
Unit of Measure

Operating Function

0 - off

N/A
 

1 - back purge

N/A
 

2 - sample

N/A
 

3 - needle purge

N/A
 

4 - off

N/A
 

Specifications

Material

N/A Stainless Steel (SS) 316 Stainless Steel (SS) 316L

Sleeve Type

N/A 60 cc sleeve with bottle retaining clip

Needle Assembly

N/A Single piece VTO needle assembly with vent to outlet connection 1/4" FNPT
Process/vent needle ID: 1.35 mm

Valves

N/A

Four-way ball valve type H791
Fluorocarbons (FKM) A O-rings
Pressure range 103 bar at 20°C (1500 psig at 70°F)
Temperature range -17/+179°C (0/+354°F)

Operation

N/A Manual

Connections

N/A 1/4" FNPT, regulator, gauge and check valve included.

Please Note

N/A

The above is a basic specification only. DOPAK® Samplers can be offered with a wide variety of options as mentioned below.

Options

N/A
  • Fixed sequence handle
  • Lockable handle
  • Mounting plate
  • Pipe stand
  • Block valve
  • Flow meter
  • Enclosure
  • Sample cooler
  • Mounting bracket
  • Steam sterilising cap
  • Welded connection
  • Continuous needle purge
  • Solvent purge
  • Exotic materials
  • Larger/smaller sample size

Applications

N/A

  • Liquids at lower pressure (P = < 8 bar)
  • Closed sampling with lower vapour pressure (P = < 0,7 bar)
  • Corrosive, hazardous liquids
  • Sampling from pipelines and tanks
  • Zero emission sampling

Video

N/A

Features

N/A

  • Sampling directly under process conditions
  • Low pressure application
  • Representative sample
  • Minimal dead volume
  • Closed sampling
  • No build up of sample material in needle assembly
  • Purging the sample bottle with an inert gas